Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test was conducted according to Directive 88/449/EEC and compliant with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressureopen allclose all
Temp.:
50 °C
Vapour pressure:
0.002 Pa
Remarks on result:
other: First vapour pressure
Temp.:
25 °C
Vapour pressure:
0 Pa
Remarks on result:
other: Second vapour pressure

Applicant's summary and conclusion

Conclusions:
Vapour pressure:
0.0021 Pa at 50 degree C, first vapour pressure
0.00007 Pa at 25 degree C, second vapour pressure