Registration Dossier

Administrative data

Endpoint:
surface tension
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test was conducted according to Directive 84/449/EEC, A.5 and compliant with GLP.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1993

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.5 (Surface Tension)
Deviations:
not specified
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Surface tension
Surface tension:
58.8 mN/m
Temp.:
20 °C
Conc.:
5 000 mg/L

Applicant's summary and conclusion

Conclusions:
Surface tension of the substance: 58.8 mN/m at 20 degree C, concentraiton: 5000 mg/L