Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 267-051-0 | CAS number: 67774-74-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Density
Administrative data
Link to relevant study record(s)
- Endpoint:
- relative density
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 28 May 2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D4052-96
- GLP compliance:
- yes
- Type of method:
- other: digital density meter
- Type:
- density
- Density:
- 0.856 g/cm³
- Temp.:
- 20 °C
- Key result
- Type:
- relative density
- Density:
- 0.858
- Temp.:
- 20 °C
- Conclusions:
- The relative density of the test substance was 0.8577 at 20 °C.
- Executive summary:
The study was performed to determine the relative density according to the method ASTM D4052-96 and in compliance with GLP. The relative density of the test substance has been determined to be 0.8577 at 20 ˚C.
- Endpoint:
- relative density
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 14 Dec 2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D4052-96
- GLP compliance:
- yes
- Type of method:
- other: digital density meter
- Type:
- density
- Density:
- 0.864 g/cm³
- Temp.:
- 20 °C
- Key result
- Type:
- relative density
- Density:
- 0.865
- Temp.:
- 20 °C
- Conclusions:
- The relative density of the test substance was 0.8652 at 20 ˚C.
- Executive summary:
The study was performed for determing the relative density according to the method ASTM D4052-96 and in compliance with GLP. The relative density of the test substance has been determined to be 0.8652 at 20 ˚C.
- Endpoint:
- relative density
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- 14 Dec 2009
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- test procedure in accordance with national standard methods
- Qualifier:
- according to guideline
- Guideline:
- other: ASTM D4052-96
- GLP compliance:
- yes
- Type of method:
- other: digital density meter
- Type:
- density
- Density:
- 0.857 g/cm³
- Temp.:
- 20 °C
- Key result
- Type:
- relative density
- Density:
- 0.859
- Temp.:
- 20 °C
- Conclusions:
- The relative density of the test substance was 0.8587 at 20 ˚C.
- Executive summary:
The study was performed for determing the relative density according to the method ASTM D4052-96 and in compliance with GLP. The relative density of the test substance has been determined to be 0.8587 at 20 ˚C
Referenceopen allclose all
Description of key information
The relative density of the test subtstance was conducted according to the ASTM D4052-96 test by using the digital density meter method and was found to be 0.856 - 0.866.
Key value for chemical safety assessment
- Relative density at 20C:
- 0.856
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.