Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 Apr 2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Version / remarks:
Version 78 (2005)
GLP compliance:
yes
Key result
Auto-ignition temperature:
229 °C
Atm. press.:
101.9 kPa
Conclusions:
The auto ignition temperature was 229 °C at 101.9 kPa.
Executive summary:

The auto flammibility of the test substance has been determined in accordance with ASTM E659 and in compliance with GLP. The auto ignition temperature was observed at 229 °C at 101.9 kPa.

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Version / remarks:
Version 78 (2005)
GLP compliance:
yes
Auto-ignition temperature:
280 °C
Atm. press.:
102.9 kPa
Conclusions:
The auto ignition temperature was 280 °C at 102.9 kPa.
Executive summary:

The auto flammibility of the test substance has been determined in accordance with ASTM E659 and in compliance with GLP. The auto ignition temperature was observed at 280 °C at 102.9 kPa.

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
25 Jan 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
Version / remarks:
Version 78 (2005)
GLP compliance:
yes
Auto-ignition temperature:
250 °C
Atm. press.:
102.9 kPa
Conclusions:
The auto ignition temperature was 250 °C.
Executive summary:

The auto flammibility of the test substance has been determined in accordance with ASTM E659 and in compliance with GLP. The auto ignition temperature was observed at 250 °C at 102.9 kPa.

Description of key information

The Auto flammability of the test subtstance in a ASTM E659 -78 study and was found ranging from 229 to 280 °C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
229 °C

Additional information