Description of key information

The test substance does not melt under the conditions of the test.

Key value for chemical safety assessment

Additional information

In a GLP compliant study performed according to EC method A.1, the melting point of the test substance was determined (RCC 2005). No melting was observed below 400°C, but an exothermic effect could be observed starting at about 250°C. After the experiment, the sample had lost about 19% of its mass and it was still a black powder.