Registration Dossier

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
other: Body responsible for the test
Title:
Unnamed
Year:
1995

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: EG A.4 Dampfdruckwaage
GLP compliance:
yes

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
29.9 °C
Vapour pressure:
1.64 Pa
Remarks on result:
other: first vapour pressure 0.52Pa 18.1°C second vapour pressure 1.03Pa 25°C Estimated vapour pressure value.