Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
basic toxicokinetics in vitro / ex vivo
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)

Data source

Reference
Reference Type:
publication
Title:
Percutaneous absorption of polycyclic aromatic compounds from bitumen fume condensate
Author:
Roy, T. A., Kriech, A. J. and Mackerer, C. R.
Year:
2007
Bibliographic source:
J. Occup. and Env. Hygiene, Volume 4, No. 81, Pages 137-143

Materials and methods

Objective of study:
absorption
Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
Test material applied to sections of isolated human back skin mounted in a Franz diffusion cell. Dermal uptake was monitored by diffusion of material from the skin surface through to a receptor fluid.
Sections of human back skin were sliced with a dermatome to a thickness of ~250 µm, and 1-inch circular pieces were mounted in 6 Franz diffusion  cells.  Tissue integrity was assured by measurement of electrical resistance.  Neat condensate was applied to the stratum corneum at "infinite dose" (200 µl) while the dermis was in direct contact with a receptor fluid  vessel consisting of an aqueous solution of polyoxyethylene 20 oleyl  ether.  
Receptor fluids were sampled at 12 intervals over 48 hours, and  analyzed by an HPLC system equipped with a variable wavelength detector  and a fluorescence
detector connected in series.  The UV detector was operated at 254 nm, and the fluorescence detector at  ex630nm/em400nm, 18 nm bandpass. 
The mobile phase was a 60-100%  acetonitrile/water gradient. 
Penetration rates of anthracene,  fluoranthrene-pyrene, and total 3-6 ring polycyclic aromatic compounds (PAC) were measured.
GLP compliance:
not specified

Test material

Constituent 1
Reference substance name:
Asphalt, oxidized
EC Number:
265-196-4
EC Name:
Asphalt, oxidized
Cas Number:
64742-93-4
IUPAC Name:
Asphalt, oxidized
Test material form:
other: low viscosity liquid hydrocarbon
Radiolabelling:
no

Test animals

Species:
human
Sex:
not specified

Administration / exposure

Route of administration:
dermal
Vehicle:
unchanged (no vehicle)
Details on exposure:
neat bitumen fume condensate (200ul) applied to the surface of skin samples (n=6) held in a Franz diffusion cell.
Duration and frequency of treatment / exposure:
Single application
Doses / concentrations
Remarks:
Doses / Concentrations:
200 ul
No. of animals per sex per dose / concentration:
6 skin samples
Control animals:
no
Details on study design:
six skin samples used for the study. Aliquotes of the test material applied to the surface of skin samples mounted in Franz diffusion cells. The receptor fluid was sampled at 0, 2,4,8,12, 16, 20, 24, 30, 36 and 48 hrs after application and analysed for the presence of polycyclic aromatic hydrocarbon by HPLC.
Details on dosing and sampling:
test material applied (200 ul) using a positive displacemnt pipette.

Results and discussion

Toxicokinetic / pharmacokinetic studies

Details on absorption:
The rates of dermal penetration (ng/cm²/hr±SD) were: 
anthracene 6.5 ± 0.9;  
fluoranthene-pyrene 1.8 ± 0.3;
3-6 ring PAC 120 ± 30.  

Percentages of  applied dose absorbed were: 
anthracene 5.3%, 
fluoranthene-pyrene 3.3%,
 3-6 ring PAC 1.8%.  

The apparent permeability coefficient Kp (Kp =  flux rate/applied concentration) for anthracene was 2 x 10-4 cm/hr.

Bioaccessibility (or Bioavailability)

Bioaccessibility (or Bioavailability) testing results:
 These results demonstrate that dermal penetration of PAC, at low concentrations  found in bitumen fume condensates can be measured by an 
appropriately designed in vitro method.

Applicant's summary and conclusion

Conclusions:
Interpretation of results (migrated information): other: These results demonstrate that dermal penetration of PAC occurs, at  low concentrations  found in bitumen fume condensates.
Dermal penetration of PACs found in low concenetrations in bitumen fume condensate can occur. The amount amd rate of dermal uptake was relatively low.
Executive summary:

In an in-vitro dermal absorption study, 200 ul aliquots of neat bituen fume condensate, containing low concentrations of PACs, was applied to the surface of human skin samples fixed in a Franz Diffusion cell. Samples of the receptor fluid were analysed at time intervals ovr a 48hr period following application.

Results show that PACs present in bitumen fume condensate can penetrate the skin.

The rate of dermal flux (ng/cm²/hr±SD) for selected PACs was:

anthracene  6.5 ± 0.9;  fluoranthene-pyrene 1.8 ± 0.3; whilst the rate for total 3-6 ring PAC was 120 ± 30.  

The amount absorbed over a 48hr period was relatively low; measured values compared to aapplied dose were

anthracene 5.3%, fluoranthene-pyrene 3.3% and  3-6 ring PAC 1.8%.  

The permeability coefficient Kp (Kp =  flux rate/applied concentration) for anthracene was calculated to be 2 x 10-4 cm/hr.