Registration Dossier

Physical & Chemical properties

Additional physico-chemical information

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
additional physico-chemical information
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
2009-11-28 to 2010-03-15
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to
Guideline:
other: Method N.4 of the UN Transport of Dangerous Goods, Manual of Test and Criteria, fourth revised edition, 2003.
Deviations:
no
GLP compliance:
yes (incl. certificate)
Remarks:
performed in accordance with UK GLP standards (Schedule 1, Good Laboratory Practice Regulations 1999 (SI 1999/3106 as ammended by SI 2004/0994)).
Endpoint investigated:
other: oxidative self heating
Results:
No signs of self-ignition or self heating were observed during the course of the test.
Conclusions:
The test material was found to be negative for self-heating.
Executive summary:

Under the conditions of the test (Method N.4 of the UN Transport of Dangerous Goods, Manual of Test and Criteria, fourth revised edition, 2003.), the test material was found to not undergo oxidative self heating.

Description of key information

Under the conditions of the test (Method N.4 of the UN Transport of Dangerous Goods, Manual of Test and Criteria, fourth revised edition, 2003.), the test material was found to not undergo oxidative self heating.

Additional information