Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
01 April 2019
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ISO 2592 (Determination of flash and fire points - Cleveland open cup method)
Version / remarks:
ASTM Standard D92-12b,, Standard Test Method for Flash and Fire Points by Cleveland Open Cup Tester”, ASTM International, West Conshohocken, PA
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
open cup
Key result
Remarks on result:
no flash point up to 100°C
Remarks:
BOILED @ 104
Interpretation of results:
GHS criteria not met
Conclusions:
In an ASTM D921 study Reaction products of monoethanolamine and boric acid 1:3 dd not produce a flashpoint up to 100°C.

Description of key information

In an ASTM D921 study Reaction products of monoethanolamine and boric acid 1:3 dd not produce a flashpoint up to 100°C.

Key value for chemical safety assessment

Additional information