Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Basic toxicokinetics

Currently viewing:

Administrative data

Endpoint:
basic toxicokinetics in vitro / ex vivo
Remarks:
Bioaccessibility - transformation/dissolution in artificial physiological media
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-08-14 to 2013-01-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Objective of study:
bioaccessibility (or bioavailability)
Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
Deviations:
yes
Remarks:
Bioaccessibility testing: loading of 100 mg/L; five artificial physiological media agitated at 100 rpm, at 37 °C ± 2 °C; sampling after 2h and 24h; determination of Zr and Fe concentrations after filtration by ICP-MS and ICP-OES.
Principles of method if other than guideline:
An internationally agreed guideline does not exist for this test (e.g. OECD). However, similar tests have been conducted with several metal compounds, including steels, in previous risk assessments (completed under Regulation (EEC) No 793/93) and in recent preparation for REACH regulation (EC) No 1907/2006.
The test was performed on the basis of the guidance for OECD-Series on testing and assessment Number 29 and according to the bioaccessibility test protocol provided by the study monitor.
GLP compliance:
yes (incl. QA statement)
Remarks:
2011-02-07

Test material