Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The test item C-SAT 100013 has a vapour pressure of < 1.0*10-1 Pa (1.0 *10'3 mbar) at 20 ·C according to the definition in the OECD Guideline 104 (Grain-Watson estimation).

Key value for chemical safety assessment

Vapour pressure:
0.1 Pa
at the temperature of:
20 °C

Additional information

The vapour pressure of the test item C-SAT 100013 was determined in accordance with the test method OECD Guideline 104 "OECD Guideline For The Testing Of Chemicals, adopted by the Council on 23 March 2006 , Vapour Pressure" (similar to the test method AA. "Vapour Pressure according to the Dynamic Method" as described in the Official Journal of the European Communities L383A).

The test item C-SAT 100013 has a vapour pressure of < 1.0*10-1 Pa (1.0 *10'3 mbar) at 20 ·C according to the definition in the OECD Guideline 104 (Grain-Watson estimation).

The finding is supported by the use of QSAR analyses (EPIWIN, v.1.43). A vapour pressure of 0.0399 Pa was estimated at 20°C and 0.433 Pa at 40°C.