Administrative data

First-aid measures

On contact with eyes: Flush with water.

On skin contact: Flush with water.

If inhaled: Remove to fresh air.

On ingestion: Obtain medical attention.

Fire-fighting measures

Suitable extinguishing media:

On large fires use dry chemical, foam or water spray (fog). On small fires use carbon

dioxide (CO2), dry chemical or water spray. Water can be used to cool fire exposed

containers.

Unsuitable extinguishing media:

None known.

Hazards during fire fighting:

Vapours may form explosive mixtures with air.

Special protective equipment/procedures:

A self-contained respirator and protective clothing should be worn. Determine the need

to evacuate or isolate the area according to your local emergency plan. Use water spray to keep fire exposed containers cool.

Hazardous Combustion Products:

Thermal breakdown of this product during fire or very high heat conditions may evolve

the following decomposition products: Silica. Carbon oxides and traces of incompletely

burned carbon compounds.

Accidental release measures

Personal precautions:

Wear proper protective equipment.

Environmental precautions:

Prevent from spreading or entering into drains, ditches or rivers by using sand, earth or

other appropriate barriers.

Methods for cleaning up:

Determine the need to evacuate or isolate the area according to your local emergency

plan. Very large spills should be contained by bunding, etc... procedures. Mop, wipe or

soak up with absorbent material and place in a container with a lid. The spilled product

produces an extremely slippery surface.

Handling and storage

Advice on safe handling:

General ventilation is required. Local ventilation is recommended. Do not breathe

vapour. Do not ingest. Avoid eye contact.

Advice on storage:

Do not store with oxidizing agents.

Vapours may form explosive mixtures with air.

Specific uses:

Refer to technical data sheet available on request.

Unsuitable packaging materials:

None known.

Transport information

Land transport (UN RTDG/ADR/RID)

UN number:
Not subject to ADR/RID.
Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (UN RTDG/ADN(R))

UN number:
Not subject to AND(R) code.
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

UN number:
Not subject to IMDG code.
Shippingopen allclose all
Remarksopen allclose all

Air transport (UN RTDG/ICAO/IATA)

UN number:
Not subject to IATA regulations.
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Engineering Controls:

Ventilation : Refer to Section "Handling and storage".

Exposure controls for hazardous components

Name                                                                  CAS-No. Exposure                                  Limits

1,6-Bis(trimethoxysilyl)hexane                     87135-01-1                                             250 ppm STEL as methanol

                                                                                                                                               200 ppm TWA as methanol

                                                                                                                                               333 mg/m3 STEL as methanol

                                                                                                                                               266 mg/m3 TWA as methanol

Methanol                                                            67-56-1                                                    200 ppm TWA

                                                                                                                                               250 ppm STEL

                                                                                                                                               266 mg/m3 TWA

                                                                                                                                               333 mg/m3 STEL

                                                                                                                                               

Personal protection equipment

Respiratory protection :

Suitable respiratory protection should be worn if the product is used in large quantities,

confined spaces or in other circumstances where the OEL may be approached or exceeded.

Depending on the working conditions, wear a respiratory mask with filter(s) AX or use a

self-contained respirator.

The choice of a filter type depends on the amount and type of chemical being handled in

the workplace. Regarding filter characteristics, contact your respiratory protection

supplier.

Hand protection: Gloves are not normally required.

Eye protection: Safety glasses should be worn.

Skin protection : Protective equipment is not normally necessary.

Hygiene measures : Exercise good industrial hygiene practice. Wash after handling, especially before eating,

drinking or smoking.

Environmental exposure controls: Refer to sections "Accidental Release Measures" and "Ecological Information".                                                                    

Stability and reactivity

Stability: Stable under normal usage conditions.

Conditions to avoid : None established.

Materials to avoid : Can react with strong oxidising agents.

Hazardous decomposition products:

Thermal breakdown of this product during fire or very high heat conditions may evolve

the following decomposition products: Silica. Carbon oxides and traces of incompletely

burned carbon compounds.

Disposal considerations

Product disposal:

Dispose of in accordance with local regulations. According to the European Waste

Catalogue, Waste Codes are not product specific, but application specific. Waste codes

should be assigned by the user, preferably in discussion with the waste disposal

authorities.

Packaging disposal:

Dispose of in accordance with local regulations. Waste codes should be assigned by the

user, preferably in discussion with the waste disposal authorities.