Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Already evaluated by the Competent Authorities for Biocides and Existing Substance Regulations.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2003

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM E537-86, Method A1 of Commission Directive 92/69/EEC
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
differential scanning calorimetry

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
purity: 97%

Results and discussion

Melting / freezing point
Melting / freezing pt.:
> 673 K
Atm. press.:
ca. 101.72 kPa

Applicant's summary and conclusion

Conclusions:
>673 ± 0.5 K at 101.72 kPa
Executive summary:

>673 ± 0.5 K at 101.72 kPa