Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Parameters determined according EC test guideline

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Deviations:
no
GLP compliance:
no

Test material

Constituent 1
Chemical structure
Reference substance name:
Tin tetrachloride
EC Number:
231-588-9
EC Name:
Tin tetrachloride
Cas Number:
7646-78-8
Molecular formula:
Cl4Sn
IUPAC Name:
tin tetrachloride
Details on test material:
Batch No.: 16.02.2009

Results and discussion

Auto-ignition temperature (liquids / gases)
Auto-ignition temperature:
> 654 °C
Atm. press.:
1 013.3 hPa
Remarks on result:
other:

Any other information on results incl. tables

No self ignition was determined up to 654 °C. Therefore the performance of the main test was not necessary.

Applicant's summary and conclusion