Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 231-135-5 | CAS number: 7440-25-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Additional toxicological data
Administrative data
- Endpoint:
- additional toxicological information
- Type of information:
- experimental study
- Adequacy of study:
- weight of evidence
- Study period:
- not reported
- Reliability:
- 3 (not reliable)
- Rationale for reliability incl. deficiencies:
- other: Brief summary of experimental data, performed to non-standard methods.
Data source
Reference
- Reference Type:
- publication
- Title:
- Tissue reactions to tantalum gauza and stainless steel gauze an experimental comparison
- Author:
- Koontz AR, Kimberly RC
- Year:
- 1 953
- Bibliographic source:
- Annals of Surgery, Volume 137, Number 6, June 1953, p833-842
Materials and methods
- Type of study / information:
- Paper detailing experimental results from a study in which dogs were implanted with tantalum and stainless steel gauzes to determine their suitability for use in the surgical cure of hernias in humans.
Test guideline
- Qualifier:
- no guideline followed
- Principles of method if other than guideline:
- Approximately two inches of the rectus sheath and muscle on each side were resected through separate right and left rectus incisions in each of 76 dogs. The defect on the right was repaired by suturing in a piece of tantalum gauze, using one black silk suture in each corner of the gauze. On the left side the defect was repaired by similarly suturing in a piece of stainless steel gauze. On each side the subcutaneous tissue was closed with fine black silk, interrupted, and the skin with fine black silk, continuous. These animals were sacrificed at periods of time after operation varying from one week to 33 weeks. When animals were sacrificed, the site of each implantation was carefully observed and findings recorded.
In a follow-up study 27 dogs were treated in the same way only this time, all of the experiments were conducted in an entirely non-sterile fashion. Instruments were not sterilised and instruments, gowns and gloves were purposely contaminated. Cat gut was used to suture the materials in place. In this experiment, the average time between operation and autopsy was approximately 2 months. - GLP compliance:
- not specified
- Remarks:
- (not reported)
Test material
- Reference substance name:
- Tantalum
- EC Number:
- 231-135-5
- EC Name:
- Tantalum
- Cas Number:
- 7440-25-7
- Molecular formula:
- Ta
- IUPAC Name:
- tantalum
- Details on test material:
- - Name of test material (as cited in study report): tantalum gauze
Constituent 1
Results and discussion
Any other information on results incl. tables
Sterile experiment
In almost every instance, it was impossible to pull the tantalum gauze away from the surrounding tissues. Furthermore, there was a large amount of fibrosis visible around the tantalum gauze. Infection was seen to occur in 5 instances.
Non-sterile experiment
While all the wounds were infected and suppurated to start with, the infection cleared up in varying lengths of time and good healing took place without sinus formation. There were two cases in which infection persisted beyond time of sacrifice. Inspite of the fact that wounds were infected, excellent infiltration of fibrous tissue took place and the wounds healed nicely.
Applicant's summary and conclusion
- Conclusions:
- It was concluded that the experiments outlined that tantalum gauze had at least some advantages over stainless steel gauzes in hernia repair. More fibrosis was observed through and around the tantalum gauzes than around the stainless steel gauzes. It was found to be impossible to pull tissues away from tantalum gauze, so firmly were they intermingled with it and so tightly did they cling to it.
- Executive summary:
In an experiment in which dogs were implanted with tantalum and stainless steel gauzes to determine their suitability for use in the surgical cure of hernias in humans it was found that tantalum gauze had at least some advantages over stainless steel gauzes in hernia repair.
During the study approximately two inches of the rectus sheath and muscle on each side were resected through separate right and left rectus incisions in each of 76 dogs. The defect on the right was repaired by suturing in a piece of tantalum gauze, using one black silk suture in each corner of the gauze. On the left side the defect was repaired by similarly suturing in a piece of stainless steel gauze. On each side the subcutaneous tissue was closed with fine black silk, interrupted, and the skin with fine black silk, continuous. These animals were sacrificed at periods of time after operation varying from one week to 33 weeks. When animals were sacrificed, the site of each implantation was carefully observed and findings recorded.
In a follow-up study 27 dogs were treated in the same way only this time, all of the experiments were conducted in an entirely non-sterile fashion. Instruments were not sterilised and instruments, gowns and gloves were purposely contaminated. Cat gut was used to suture the materials in place. In this experiment, the average time between operation and autopsy was approximately 2 months.
Under the conditions of the study, it was impossible to pull the tantalum gauze away from the surrounding tissues. Furthermore, there was a large amount of fibrosis visible around the tantalum gauze. Tantalum was also seen to exhbit a healing effect in the non-sterile experiment as, in most cases, the infection cleared up in varying lengths of time and good healing took place without sinus formation. There were two cases in which infection persisted beyond time of sacrifice. Inspite of the fact that wounds were infected, excellent infiltration of fibrous tissue took place and the wounds healed nicely.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.