Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
29NOV2022
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
not specified
Type of method:
equilibrium method closed cup
Flash point apparatus:
other: Normalab NPV Tech
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source (i.e. manufacturer or supplier) and lot/batch number of test material:
Evonik Operations GmbH, Sample No SPZ22-243-1, Charge UC19C04512
Key result
Flash point:
ca. 133.5 °C
Atm. press.:
ca. 101.3 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the sample corrected to an air pressure of 101.3 kPa is 133.5 °C.

Description of key information

The flash point of the sample corrected to an air pressure of 101.3 kPa is 133.5 °C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
133.5 °C

Additional information