Registration Dossier

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Data waiving:
other justification
Justification for data waiving:
other:

Description of key information

Endpoint is waived: the test method is not applicable because the substance decomposes under test conditions.

Key value for chemical safety assessment

Additional information

Test method is not applicable because substance decomposes under test conditions. Self-Accerelating Decomposition Temperature (SADT) of the substance is 80 °C (reference SADT: CLP regulations 2.15.2.3 and UN Recommendations on the Transport of Dangerous Goods, Manual of Tests and Criteria, 5th revised edition, sub-sections 28.1, 28.2, 28.3 and Table 28.3.)

See also ECHA guidance on the application of the CLP criteria, section 2.14.

See: 4.13 Flammability