Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: The test was performed according to an industry accepted guideline.

Data source

Reference
Reference Type:
other company data
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
Deviations:
no
GLP compliance:
no
Remarks:
ISO 9001/2000 Certified
Type of method:
non-equilibrium method closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate)
EC Number:
224-235-5
EC Name:
Zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate)
Cas Number:
4259-15-8
Molecular formula:
Too complex
IUPAC Name:
1-Hexanol, 2-ethyl-, O,O-diester with phosphorodithioic acid, zinc salt

Results and discussion

Flash point
Flash point:
147 °C
Atm. press.:
760 mm Hg

Applicant's summary and conclusion

Conclusions:
The flash point of the test material is 147 deg. C at 760 mmHg
Executive summary:

The flash point of the test substance, determined by the Pensky-Martens closed cup method, is 147 deg. C at 760 mm Hg.