Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
other information
Study period:
2002-04-10
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2002
Report Date:
2002

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. certificate)
Type of method:
closed cup
Remarks:
Abel Pensky

Test material

Reference
Name:
Unnamed
Type:
Constituent
Details on test material:
Batch No. QB 14766
Analytical purity: 98.0 %

Results and discussion

Flash point
Flash point:
41.5 °C
Atm. press.:
96.48 kPa

Any other information on results incl. tables

test

measured value [°C]

corrected value [°C]

mean value [°C]*

1.

39.6

40.8

41.5

2.

40.6

41.8

*The mean value is rounded to + 0.5 °C

Applicant's summary and conclusion