Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1990
Report date:
1990

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
Type of method:
rotational viscometer (dynamic)

Test material

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
16 900
Remarks on result:
other:
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
1 290
Remarks on result:
other: