Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Oxidising properties

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
oxidising solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because there are no chemical groups present in the molecule which are associated with oxidising properties and hence, the classification procedure does not need to be applied
Endpoint:
oxidising gases
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid
Endpoint:
oxidising liquids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a solid

Description of key information

Consideration of the test item as an oxidising gas is not required because the substance is a solid.

 

Consideration of the test item as an oxidising liquid is not required because the substance is a solid.

 

The result for oxidising properties was predicted negative based on the chemical structure of the solid test item.

Key value for chemical safety assessment

Oxidising properties:
no

Additional information

Under COLUMN 2 “SPECIFIC RULES FOR ADAPTATION FROM COLUMN 1” in the REGULATION (EC) No 1907/2006 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 18 December 2006, it states The study does not need to be conducted if: “the substance is incapable of reacting exothermically with combustible materials, for example on the basis of the chemical structure” accordingly “The structure of the test material was assessed for chemical groups that would imply oxidising properties. Examples of such groups are nitrates, metal oxides, hypofluorites, difluoroaminopolynitroaryls, perchlorates, bromates and iodites.” The oxidising properties were predicted using Method A17 Oxidising Properties (Solids) of Commission Regulation (EC) No 440/2008 of 30 May 2008. Based on the chemical structure the result for the oxidising properties has been predicted negative.

Justification for classification or non-classification

The result for oxidising properties was predicted negative based on the chemical structure of the test item and classification in accordance with Regulation (EC) No 1272/2008 is unnecessary.