Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable liquids: obsolete as covered by section 'Flash point'
Type of information:
calculation (if not (Q)SAR)
Remarks:
estimated by calculation
Adequacy of study:
weight of evidence
Study period:
1994
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: extrapolated data
Qualifier:
according to guideline
Guideline:
other: extrapolated
Principles of method if other than guideline:
Data extrapolated from published literature: Nabert and Schon, 1994.
GLP compliance:
no
Remarks:
extrapolated data
Interpretation of results:
other: Flammable
Remarks:
based on flash point data
Conclusions:
The extrapolated lower and upper flammability limit are respectively 0.6 and 7.0 v%.
Executive summary:

The extrapolated lower and upper flammability limit are respectively 0.6 and 7.0 v%.

Endpoint:
flammable solids
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is a liquid

Description of key information

The lower and upper flammability limit have been estimated at 0.6 and 7.0 v% respectively.

Key value for chemical safety assessment

Flammability:
flammable

Additional information

Justification for classification or non-classification

The classification flammable is determined by the flash point (> 35°C) and the initial boiling point of the substance.