Registration Dossier

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Substance decomposes during vapour pressure testing (OECD 104). Because of rapid hydrolysis, vapour pressure of 2-ethylhexanol released from the substance is used in CSA. 

Key value for chemical safety assessment

Vapour pressure:
1 hPa
at the temperature of:
20 °C

Additional information

The isothermal TGA effusion method by using OECD 104 in acordance with GLP was applied for the determination of the vapour pressure of the substance. The vapour pressure could not be determined as the test substance decomposes.

Titanium tetrakis(2-ethylhexanolate) is hydrolytically unstable. When it comes in contact with water or moisture, a complete hydrolysis will take place with no significant reaction products other than 2 -ethylhexanol (2 -EH) and hydrated titanium dioxide. Because of rapid hydrolysis, read-across data on the vapour pressure of 2 -EH released from the substance is used as a key value in CSA (peer-reviewed secondary source Lide (2008) and experimental data by Muller 2009).