Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
EU Method A.4 (Vapour Pressure)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Remarks:
method is outside its recommendad range, however, result can be be calculated with adequate precision

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Vapour pressure
Temp.:
20 °C
Vapour pressure:
0 hPa
Remarks on result:
other: see also "Conclusions" for vapour pressure at different temperatures and in section "Attached background material"

Applicant's summary and conclusion

Conclusions:
20°C: 8.0 x 10exp-9 hPa; 25°C: 1.9 x 10exp-8 hPa; 50°C: 9.2 x 10exp-7 hPa