Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

No flash-point could be determined for FORMAMIDOPROPYLBETAINE using the PenskyMartens closed cup method. 
No flammable vapour/air mixture was produced in the test vessel at temperatures below boiling, which was observed visually at 108 °C.

Key value for chemical safety assessment

Additional information

The determination of the flash-point of the test substance was performed in accordance with EEC-Directive 92/69 EEC, A.9 "Flash-point" (1992), ISO 2719 "Determination of flash pointPensky Martens closed cup method" (2002) and ASTM D 93 "Standard Test Methods for Flash Point by Pensky-Martens Closed Cup Tester" (2002).

A Pensky-Martens Closed Cup automatic flash-point tester was used.

No flash-point could be determined for FORMAMIDOPROPYLBETAINE using the PenskyMartens closed cup method. No flammable vapour/air mixture was produced in the test vessel at temperatures below boiling, which was observed visually at 108 °C.