Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable gases
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Followed a standard test guidline that is valid for the endpoint. GLP certified laboratory (Intertek)
Qualifier:
according to guideline
Guideline:
other: Intertek method
Deviations:
not specified
Principles of method if other than guideline:
Test performed at atmospheric pressure using vertical flame propagation in a closed 2 liter capacity, aluminum alloy vertical tube (100 mm diameter, 260 mm long) held within a temperature-controlled enclosure. Ignition by high tension spark gap mounted 10 mm above the base of the explosion tube.
GLP compliance:
yes
Remarks:
Certified lab Intertek

Results for lower and upper flammable limits (LFL & UFL)

Interpretation of results:
flammable
Remarks:
Migrated information
Conclusions:
Isotridecyl alcohol has a low degree of flammability (Flash point = 120 ° C.).
Executive summary:

Isotridecyl alcohol has a low degree of flammability (Flash point = 120 ° C.).

Description of key information

Isotridecyl alcohol has a low degree of flammability, not classified as flammable.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Isotridecyl alcohol has a low degree of flammability, not classified as flammable.

Justification for classification or non-classification

Flash point >100 deg C