Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 233-297-2 | CAS number: 10108-73-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Flammability
Administrative data
Link to relevant study record(s)
- Endpoint:
- flammable solids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from 10 JUN 2005 to 13 OCT 2005
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Reason / purpose for cross-reference:
- reference to same study
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.10 (Flammability (Solids))
- Version / remarks:
- Cited as Directive 92/69/EEC, A.10
- Deviations:
- yes
- Remarks:
- Ignition source: use of a platinum wire heated by electrical power instead a direct flame. This modification has no effect on the conclusion.
- GLP compliance:
- yes (incl. QA statement)
- Key result
- Test procedure:
- burning rate test: preliminary screening test
- Remarks on result:
- substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The test item is not highly flammable under the conditions of test.
- Executive summary:
The determination of the flammability of cerium trinitrate was performed using a powder train about 250 mm long, according to EU Method A10.
The test item did not burn. No further testing was required. It is not highly flammable under the conditions of test.
- Endpoint:
- substances / mixtures which in contact with water emit flammable gases
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water
- Endpoint:
- pyrophoric solids
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
- Endpoint:
- self-heating substances / mixtures
- Data waiving:
- study scientifically not necessary / other information available
- Justification for data waiving:
- other:
Referenceopen allclose all
The test item did not burn. No further testing was required.
Description of key information
Following a GLP study in accordance with EC test method A.10, cerium trinitrate is concluded to be not highly flammable (Cerutti, 2005). From day to day handling of the substance, cerium trinitrate is concluded not to have pyrophoric properties nor to be flammable in contact with water. Finally, the substance is not considered self-heating, based on the observations of a GLP study performed according to EC test method A.16 and an additional Grewer oven test, in which the temperature of the test item did not deviate from that in the oven up to at least 400°C (Cerutti, 2005).
Key value for chemical safety assessment
- Flammability:
- not classified
Additional information
Justification for classification or non-classification
Pyrophoricity.
In the daily use and handling of cerium trinitrate during which continuous exposure to air can occur, no spontaneous ignition is observed. The absence of structural alerts furthermore confirms that it is highly unlikely that cerium trinitrate
has pyrophoric properties.
Flammability in contact with water.
Under conditions where cerium trinitrate is in contact with water (which includes the production of cerium trinitrate in aqueous solutions as applied by some manufacturers) no ignition and/or liberation of flammable gases is observed. The absence of structural alerts furthermore confirms that it is highly unlikely that cerium trinitrate is flammable in contact with water.
Flammability.
From a flammability test (EC A.10) cerium trinitrate is concluded to be not highly flammable (Cerutti, 2005). This results in an absence of classification under the CLP regulation.
Self-heating.
In an EC A.16 test and an additional Grewer oven test, the temperature of the test item did not deviate from the oven temperature up to at least 400°C (Cerutti, 2005). Based on these results, it can be safely concluded that cerium trinitrate is not self-heating.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.