Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
from December l2th, 1988 to February 9th, 1989.
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study performed according to the Test Guidelines A.4 of the EEC Directive 84/449/EEC.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1989
Report date:
1989

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes
Type of method:
gas saturation method

Test material

Constituent 1
Chemical structure
Reference substance name:
-
EC Number:
404-740-9
EC Name:
-
Cas Number:
115895-09-5
Molecular formula:
C26H40Cl2O5
IUPAC Name:
ethyl 3,5-dichloro-4-hexadecyloxycarbonyloxybenzoate
Details on test material:
Name : AF-366
Appearance : white powder
Purity : 97.5 %

Results and discussion

Vapour pressure
Temp.:
25 °C
Vapour pressure:
<= 0 Pa

Applicant's summary and conclusion

Conclusions:
The test substance has en extremely low vapour pressure at 25°C.
The actual value of the saturated vapour pressure of the test substance
may be considered to be at least one order of magnitude smaller than
0.0000001 Pa (0.000000001 mm Hg) which is the lower limit of the vapour pressure to
be determined with the gas saturation method given in the EEC Test
Guideline A.4.