Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 931-485-5 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- June 2010
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- other: GLP study performed according to OECD guideline 117 and EU Method A.8
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 010
- Report date:
- 2010
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Remarks:
- Food and Consumer Product Safety Authority (VWA), The Netherlands
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
Test material
- Reference substance name:
- 2-chloropropene
- EC Number:
- 209-187-5
- EC Name:
- 2-chloropropene
- Cas Number:
- 557-98-2
- Molecular formula:
- C3H5Cl
- IUPAC Name:
- 2-chloroprop-1-ene
- Reference substance name:
- 2-chloropropane
- EC Number:
- 200-858-8
- EC Name:
- 2-chloropropane
- Cas Number:
- 75-29-6
- Molecular formula:
- C3H7Cl
- IUPAC Name:
- 2-chloropropane
- Reference substance name:
- 1-chloropropene
- EC Number:
- 209-675-8
- EC Name:
- 1-chloropropene
- Cas Number:
- 590-21-6
- IUPAC Name:
- 1-chloroprop-1-ene
- Details on test material:
- Identification Reaction mass containing mainly 2-chloropropene
Molecular formula C3H5Cl
Molecular weight 76.53
CAS Number 557-98-2
Description Clear light yellow to brown liquid (determined at NOTOX)
Batch RBA100301A
Purity Minimum 60.0%
Test substance storage In refrigerator (2-8°C) in the dark
Stability under storage conditions Stable
Expiry date 08 March 2011 (allocated by NOTOX, 1 year after receipt of the test substance)
Constituent 1
Constituent 2
Constituent 3
Study design
- Analytical method:
- high-performance liquid chromatography
Results and discussion
Partition coefficient
- Type:
- log Pow
- Partition coefficient:
- 2.1
Any other information on results incl. tables
Calculation method:
Calculation of the Pow
The Powof the test substance was calculated to be 27.5(log Pow1.44) using the Rekker calculation method.
Calculation of the pKa
No pKavalues for acidic and basic groups in the molecular structure of the test substance in the logarithm range of 1 – 14 were calculated.
HPLC Method
In the HPLC chromatogram of the test substance solution, one large test substance peak and two small peaks obtained from impurities were observed.
The results of the HPLC method are given in the Table10. The calibration curve of the log k’ of the reference substances as function of log Pow showed that the equation of the regression line was: log k’ = 0.596´log Pow- 0.516 (r = 0.9992, n = 12).
Table10 Powat neutral pH
Substance |
tr,1 |
tr,2 |
mean tr |
log Pow |
Pow |
Area |
|
|
|
|
|
|
|
Formamide (t0) |
1.124 |
1.122 |
1.123 |
|
|
|
|
|
|
|
|
|
|
Ethylmethylketone |
1.666 |
1.662 |
|
0.3 |
|
|
Benzylalcohol |
2.555 |
2.543 |
|
1.1 |
|
|
Nitrobenzene |
5.729 |
5.695 |
|
1.9 |
|
|
Toluene |
16.586 |
16.520 |
|
2.7 |
|
|
Bromobenzene |
21.531 |
21.431 |
|
3.0 |
|
|
1,4-Dichlorobenzene |
36.589 |
36.373 |
|
3.4 |
|
|
|
|
|
|
|
|
|
Impurity I |
4.810 |
4.799 |
4.805 |
1.7 |
5.4´101 |
0.71 |
Impurity II |
6.653 |
6.630 |
6.642 |
2.0 |
1.1´102 |
0.99 |
Test substance |
7.615 |
7.598 |
7.607 |
2.1 |
1.4´102 |
98.3 |
|
|
|
|
|
|
|
Applicant's summary and conclusion
- Executive summary:
The HPLC method was chosen for the determination of the partition coefficient of the reaction mass containing mainly 2-chloropropene.
The Powand log Powvalue of the test substance and impurities with a peak area of < 1% was:
Pow
log Pow
Area
%Test substance
1.4´102
2.1
98.3
Impurity I
5.4´101
1.7
0.71
Impurity II
1.1´102
2.0
0.99
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.