Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2016
Report date:
2016

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Test Guideline 114 (Viscosity of Liquids)
GLP compliance:
yes (incl. QA statement)
Type of method:
capillary viscometer (static)

Test material

Constituent 1
Chemical structure
Reference substance name:
1-hydroxy-2-methylpentan-3-one
EC Number:
939-893-5
Cas Number:
27970-79-2
Molecular formula:
C6 H12 O2
IUPAC Name:
1-hydroxy-2-methylpentan-3-one
Test material form:
other: liquid
Details on test material:
Name of test material (as cited in study report): 1-Hydroxy-2-Methyl-3-Pentanone
Analytical purity: The purity determined by GC-FID on a DB-5 capillary column is 90.6 area-% as a mean value of two injections of the test item,
corrected to the water content.
Impurities (identity and concentrations): 0.3 g/100g water
Lot/batch No.: J 1812
Storage condition of test material: Room temperature, protection against light and humidity

Results and discussion

Viscosityopen allclose all
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
5.05
Temp.:
40°C
Parameter:
dynamic viscosity (in mPa s)
Value:
2.93
Temp.:
20°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
5.25
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
3.09

Any other information on results incl. tables

Results in detail

Viscosity determination of the test item at 20 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

5.2441

5.0480

2nddetermination

5.2525

5.0561

Mean value

5.25

5.05

*)calculated with a density of the test item ofρ= 0.9626 g/ml

 

Viscosity determination of the test item at 40 °C

 

Kinematic viscosity

[mm2/s]

Dynamic viscosity*)

[mPa*s]

1stdetermination

3.1659

2.9962

2nddetermination

3.0645

2.9002

3rddetermination

3.0571

2.8932

4thdetermination

3.0918

2.9261

Mean value

3.09

2.93

*)calculated with a density of the test item ofρ= 0.9464 g/ml

The estimated accuracy is ± 2 %.

Applicant's summary and conclusion