Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Ecotoxicological information

Toxicity to microorganisms

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The effect of the test item on the respiration of activated sewage sludge micro-organisms gave a 3-Hour EC50 of greater than 1000 mg/l.  The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/l.

Key value for chemical safety assessment

EC10 or NOEC for microorganisms:
1 000 mg/L

Additional information

Introduction.

A study was performed to assess the effect of the test item on the respiration of activated sewage sludge. The method followed was designed to be compatible with the OECD Guidelines for Testing of Chemicals (1984) No 209 "Activated Sludge, Respiration Inhibition Test", Method C.11 of Commission Regulation (EC) No. 440/2008 and US EPA Draft Ecological Effects Test Guidelines OPPTS 850.6800.

Methods. 

Activated sewage sludge was exposed to an aqueous solution of the test item at concentrations of 10, 32, 100, 320 and 1000 mg/l for a period of 3 hours at a temperature of 21±1°C with the addition of a synthetic sewage as a respiratory substrate.

The rate of respiration was determined after 3 hours contact tiand compared to data for the control and a reference item, 3,5-dichlorophenol.

Results

The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50of greater than 1000 mg/l. The No Observed Effect Concentration (NOEC) after 3 hours exposure was1000mg/l.

It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/l.