Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Water solubility

Currently viewing:

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
supporting study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Remarks:
Authoritative secondary source

Data source

Reference
Reference Type:
review article or handbook
Title:
Pentanoyl chloride
Author:
GESTIS
Year:
2020
Bibliographic source:
GESTIS - Substance database of 'Berufsgenossenschaftlichen Instituts für Arbeitsschutz' (BGIA) online query 2020-04-06

Materials and methods

Test guideline
Qualifier:
no guideline available
Principles of method if other than guideline:
Data from handbook or collection of data no data about the method was available.
GLP compliance:
not specified
Type of method:
other: not determinable

Test material

Constituent 1
Chemical structure
Reference substance name:
Valeryl chloride
EC Number:
211-330-1
EC Name:
Valeryl chloride
Cas Number:
638-29-9
Molecular formula:
C5H9ClO
IUPAC Name:
pentanoyl chloride
Test material form:
liquid

Results and discussion

Water solubility
Remarks on result:
not determinable
Remarks:
hydrolysis / violent reaction with water / hydrogen chloride gas is formed

Any other information on results incl. tables

Not determinable because of hydrolysis.

Hazardous chemical reactions:

Violent reaction with water.

Hydrogen chloride gas is formed