Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
09/11/09
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Study conducted in accordance with generally accepted scientific principles, possibly with incomplete reporting or methodological deficiencies, which do not affect the quality of relevant results.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
no

Test material

Constituent 1
Reference substance name:
Lanolin fatty acids
IUPAC Name:
Lanolin fatty acids
Constituent 2
Reference substance name:
Lanfa 2
IUPAC Name:
Lanfa 2
Constituent 3
Reference substance name:
Woolwax acids
IUPAC Name:
Woolwax acids
Details on test material:
Sponsor's identification: Lanfa 2
Description: waxy solid
Product code: LD04670
Batch number: B/371886
Storage conditions: room temperature

Results and discussion

Flammable gases (Lower and upper explosion limit)open allclose all
Parameter:
lower explosion limit
Remarks on result:
other: Not applicable
Parameter:
upper explosion limit
Remarks on result:
other: Not applicable
Aerosolsopen allclose all
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
ignition distance (cm)
Remarks:
original parameter: flame extension (cm) (migrated information)
Remarks on result:
other: Not applicable
Type of aerosol tested:
aerosol dispenser: not specified
Remarks:
or specified in description of method (migrated information)
Test parameter:
maximum flame height (cm)
Remarks:
original parameter: flame projection (cm) (migrated information)
Remarks on result:
other: Not applicable
Flammable solids
Test procedure:
burning time (test type not further specified)
Remarks:
or specified in description of method (migrated information)
Burning time:
120 s
Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

Upon applying the flame, the material quickly melted and formed a molten pool on the flame proof mat. Continued application of the flame on the pool and the solid resulted in no ignition. After 2 minutes of attempted ignition the flame was removed. A section of approximately 3 cm in length had melted and spread across the mat.

As no ignition occurred within the specified 2 minute time limit, the verdict is thus that the material is not highly flammable and no rate test is required.

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.
Executive summary:

Method

Sample of Lanfa 2 was subjected to the flammability preliminary screening test as outlined in Method A.10 pursuant to Regulation (EC) No 1907/2006 of the European Parliament and the council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH). If the preliminary test resulted in and indication of high flammability, then the burning rate test as included in Method A.10 would be carried out.

Result

Upon applying the flame, the material quickly melted and formed a molten pool on the flame proof mat. Continued application of the flame on the pool and the solid resulted in no ignition. After 2 minutes of attempted ignition the flame was removed. A section of approximately 3 cm in length had melted and spread across the mat.

As no ignition occurred within the specified 2 minute time limit, the verdict is thus that the material is not highly flammable and no rate test is required.

Conclusion

The test material has been determined to be not highly flammable as it failed to ignite in the preliminary screening test.