Registration Dossier

Guidance on Safe Use

Guidance on Safe Use

Currently viewing:

Administrative data

First-aid measures

Eye Contact - Flush with plenty of water. Seek medical attention if irritation persists.
Skin Contact - Flush the area with plenty of water. Remove material from clothing. Wash clothing before reuse.
Inhalation - Remove to fresh air.
Ingestion - Induce vomiting as directed by medical personnel. Get medical attention. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.

Fire-fighting measures

Fire Fighting Media and Instructions - Use dry chemicals, CO2, water spray or foam. Water or foam may cause frothing.
Products of combustion are carbon oxides (CO, CO2).
Firefighters and others who may be exposed to products of combustion should wear full firefighting turn out gear and self-contained breathing apparatus. Firefighting equipment should be thoroughly decontaminated after use.

Accidental release measures

Small Spill - Absorb with an inert material and place in an appropriate waste disposal container.
Large Spill - Stop the leak if possible. Remove all ignition sources. Ventilate the area involved. Absorb with an inert material and put the spilled material in an appropriate waste disposal container.

Handling and storage

Handling - Handle in accordance with good industrial hygiene and safety practices. These practices include avoiding unnecessary exposure and removal of material from eyes, skin, and clothing. Keep away from heat, sparks and sources of ignition.
Storage - Store in well ventilated area away from sources of ignition.

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

Shippingopen allclose all
Remarks
No information

Marine transport (IMDG)

Remarks
Not regulated

Air transport ICAO/IATA

Remarks
Not regulated

Additional transport information

Additional transport information
DOT (U.S.A.): Not regulated
HTS#: 2916.31

Exposure controls / personal protection

Engineering Controls - Investigate engineering controls to reduce exposures. If practical use local mechanical exhaust ventilation at
sources of air contamination such as open process equipment. Provide ventilation if necessary to minimize exposure.
Personal protection - Safety glasses or chemical splash goggles, coveralls, boots, and gloves. Suggested protective equipment might not be sufficient; consult a specialist BEFORE handling this product.
Exposure Limits - Not Available

Stability and reactivity

Stability - The product is stable.
Instability Temperature - Decomposes slowly above 270°C (5186°F) without boiling.
Conditions to Avoid - No additional remarks
Incompatibility with Various Substances - Slightly reactive to reactive with oxidizing agents, acids, and alkalis.
Corrosivity - Not considered to be corrosive for metals and glass according to our database.
Hazardous Polymerization - Will not occur.
Hazardous Decomposition Products - Not available

Disposal considerations