Registration Dossier

Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according to EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Version / remarks:
(2012)
GLP compliance:
yes (incl. certificate)
Type of method:
other: inert gas (helium) comparison pycnometer (for solids)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Densityopen allclose all
Type:
density
Density:
1.613 g/cm³
Temp.:
21.3 °C
Remarks on result:
other: Average of 3 measurements, Experiment 1
Type:
density
Density:
1.595 g/cm³
Temp.:
21.3 °C
Remarks on result:
other: Average of 3 measurements, Experiment 2
Type:
density
Density:
1.604 g/cm³
Temp.:
21.3 °C
Remarks on result:
other: Mean value of the two average values (Exp. 1+2)

Any other information on results incl. tables

The relative density of the test item at 21 °C (compared to water at 4 °C) was D420= 1.60 ± 0.02.

Applicant's summary and conclusion

Conclusions:
The relative density of the test item at 21 °C (compared to water at 4°C) was D = 1.60 ± 0.02.