Registration Dossier

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
(1995)
GLP compliance:
yes (incl. certificate)
Type of method:
capillary method

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

Melting / freezing pointopen allclose all
Melting / freezing pt.:
>= 80 - <= 88 °C
Remarks on result:
other: The test item showed a partial melting in the temperature range of 80 °C to 88 °C (capillary measurement). In the temperature range 169 °C to 192 °C a second partial melting was observed.
Melting / freezing pt.:
>= 169 - <= 192 °C
Remarks on result:
other: see above remark

Applicant's summary and conclusion

Conclusions:
The test item showed a partial melting in the temperature range of 80 °C to 88 °C (capillary measurement). In the temperature range 169 °C to 192 °C a second partial melting was observed.