Registration Dossier

Administrative data

Endpoint:
stability: thermal, sunlight, metals, other
Remarks:
Migrated from section 'Stability: thermal, sunlight, metals'
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study according EU/OECD guideline.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
OECD Guideline 113 (Screening Test for Thermal Stability and Stability in Air)
Version / remarks:
(1981)
GLP compliance:
yes (incl. certificate)

Test material

Reference
Name:
Unnamed
Type:
Constituent

Results and discussion

For thermal stability study

Test substance thermally stable:
yes

Any other information on results incl. tables

Two DSC-measurements in closed glass crucibles in high pressure crucibles showed two endothermic effects in the temperature ranges 45-105 °C and 110- 195 °C, respectively. A multistage exothermal effect was observed in the temperature range 200 - 355 °C with an energy of 1289 J/g and 1064 J/g, respectively.

Applicant's summary and conclusion

Conclusions:
The test item is thermal stable.