Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-02-12
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions (e.g. non-GLP)
Qualifier:
equivalent or similar to guideline
Guideline:
other: DIN 51562 ASTM D 445
GLP compliance:
no
Other quality assurance:
other: The laboratory complied with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005.
Type of method:
capillary viscometer (static)
Key result
Temp.:
20°C
Parameter:
dynamic viscosity (in mPa s)
Value:
4.529

The dynamic viscosity was calculated from the arithmetic mean of the kinematic viscosity (2 replicates) based on the density of the test item:

Kinematic viscosity Density nD4(20) Dynamic viscosity
1. measurement 2. measurement
20°C 5.632 mm²/s 5.596 mm²/s 0.8068 g/cm3 4.529 mPa s
40°C 3.402 mm²/s 3.411 mm²/s
Conclusions:
Low viscous organic liquid.
Dynamic viscosity (DIN 51562 / ASTM D 445): 4.529 mPa s at 20 °C.
Executive summary:

Viscosity was determined using the capillary viscosimeter method (kinematic viscosity; DIN 51562 / ASTM D 445; mean of two determinations) at 20°C and 40°C resulting in a dynamic viscosity of 4.529 mPa s.

The laboratory complied with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005.

Description of key information

Low viscous organic liquid.

Dynamic viscosity (DIN 51562 / ASTM D 445): 4.529 mPa s at 20 °C.

Key value for chemical safety assessment

Viscosity:
4.529 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

Viscosity was determined using the capillary viscosimeter method (kinematic viscosity; DIN 51562 / ASTM D 445; mean of two determinations) at 20°C and 40°C resulting in a dynamic viscosity of 4.529 mPa s.

The laboratory complied with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005.