Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010-02-12
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Comparable to guideline study with acceptable restrictions (e.g. non-GLP)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
DIN EN ISO 2719 / ASTM D93-07
GLP compliance:
no
Other quality assurance:
other: The laboratory complied with a quality management system according to DIN EN ISO 9001 : 2008 and DIN EN ISO 14001 : 2005.
Type of method:
closed cup
Remarks:
MP EN22719A/ ISO2719A
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
134 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: based on two replicate measurements

Details on single measurements:

First measurement: 134 °C;

Second measurement: 134 °C;

Mean value: 134 °C

The correction to ambient pressure (1013 hPa) was accomplished automatically during measurements by the apparatus.

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point has been determined to be at 134 °C at 1013 hPa.
Executive summary:

The flash point was determined according to DIN EN ISO 2719 using the Pensky-Martens closed cup method.

Two replicate measurements were performed, resulting in a mean flash point of 134 °C at 1013 hPa.

Description of key information

Flash point (DIN EN ISO 2719): 134 °C at 1013 hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
134 °C

Additional information

The flash point was determined according to DIN EN ISO 2719 using the Pensky-Martens closed cup method.

Two replicate measurements were performed, resulting in a mean flash point of 134 °C at 1013 hPa.