Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: guideline study and GLP

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2008
Report date:
2008

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup

Test material

Constituent 1
Chemical structure
Reference substance name:
Esterification product of castor oil and tetrahydromethyl-1,3-isobenzofuranedione
EC Number:
700-064-6
Cas Number:
2105830-60-0
Molecular formula:
Not applicable as this is a UVCB substance
IUPAC Name:
Esterification product of castor oil and tetrahydromethyl-1,3-isobenzofuranedione
Test material form:
liquid
Details on test material:
- Molecular weight: 2800-3000
- CAS Name: Castor oil. polymer with tetrahydromethyl-1,3-isobenzofurandione
- Description: Very viscous amber liquid
- Batch: NB2890-61
- Test substance storage: At room temperature in the dark under nitrogen
- Stability under storage conditions: Stable
- Expiry date: 01 January 2009

Results and discussion

Flash point
Flash point:
148 °C
Atm. press.:
102.2 kPa

Applicant's summary and conclusion

Conclusions:
The Pensky-Martens closed cup method was applied for the determination of the flash-point of the substance. The flash-point of the test substance was 148°C.
Executive summary: