Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline and well detailed study report.
Qualifier:
according to
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point:
82 °C
Atm. press.:
996 mBar
Remarks on result:
other: Corrected at the pressure of 101.3 kPa, the flash point of the substance is 82.0°C +/-0.5°C

Observation and results:

Set temperature (°C)

Corrected temperature (°C)

Test result

Remarks

Positive

Negative

70.0

70.4

 

X

 

90.0

90.4

X

 

Flash detected by apparatus

80.0

80.4

 

X

 

85.0

85.4

X

 

Flash detected by apparatus

82.0

82.4

X

 

Flash detected by apparatus

81.0

81.4

 

X

 

81.5

81.9

 

X

 

81.5

81.9

 

X

Flash point = 82.0°C (corrected : 82.4°C)

Conclusions:
The flash point of the test item, corrected at the pressure of 101.3 kPa, is 82.0°C +/- 0.5°C
Executive summary:

A guideline and well detailed study is available. The flash point of the test item, corrected at the pressure of 101.3 kPa, is found to be 82.0°C +/- 0.5°C. As a consequence the substance is not classified for flammability according to CLP regulation n°1272/2008.

Description of key information

The flash point of the test item, corrected at the pressure of 101.3 kPa, is 82.0°C +/- 0.5°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
82 °C

Additional information

A guideline and well detailed study report is available. The flash point of the test item, corrected at the pressure of 101.3 kPa, is found to be 82.0°C +/- 0.5°C. As a consequence the substance is not classified for flammability according to CLP regulation n°1272/2008.