Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
partition coefficient
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 June 2009 to 10 July 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study conducted in compliance with agreed protocols, with no or minor deviations from standard test guidelines.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2009

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.8 (Partition Coefficient)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
HPLC method
Partition coefficient type:
octanol-water

Test material

Constituent 1
Chemical structure
Reference substance name:
2,3,5,6-tetrachloropyridine
EC Number:
219-283-9
EC Name:
2,3,5,6-tetrachloropyridine
Cas Number:
2402-79-1
Molecular formula:
C5HCl4N
IUPAC Name:
2,3,5,6-tetrachloropyridine
Details on test material:
Lot number XF09160201 of purity = 99.4%

Study design

Analytical method:
high-performance liquid chromatography

Results and discussion

Partition coefficient
Type:
log Pow
Partition coefficient:
3.87
Temp.:
30 °C
pH:
7

Any other information on results incl. tables

The retention times, capacity factors and log10Powvalues determined for the sample are shown in the following table:

Injection

Retention Time (mins)

Capacity Factor (k)

Log10k

Log10Pow

1

7.424

3.68

0.566

3.87

2

7.422

3.68

0.566

3.87

Mean log10Pow:       3.87
Partition coefficient:           7.43 x 103

Applicant's summary and conclusion

Conclusions:
The partition coefficient of the test material has been determined to be 7.43 x 10E3, log10 Pow 3.87.
Executive summary:

The partition coefficient of the test material has been determined to be 7.43 x 103, log10 Pow 3.87 using theHPLC method, method A8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008.