Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
pyrophoric liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D93 (Pensky-Martin closed cup)
Deviations:
no
GLP compliance:
yes
Test procedure:
ignition time on contact with air
Remarks on result:
no ignition on contact with air (not further specified)

Sample foamed out of apparatus when heated.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
Non-flammable
Executive summary:

When tested via the ASTM Method D93 (Pensky-Martin closed cup), the test substance foamed out of apparatus when heated and was therefore determined to be non-flammable.

Description of key information

When tested via the ASTM Method D93 (Pensky-Martin closed cup), the test substance foamed out of apparatus when heated and was therefore determined to be non-flammable.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The test substance is non-flammable.

Justification for classification or non-classification

The test substance is not flammable and is not classified according to EU Classification, Labelling and Packaging of Substances and Mixtures (CLP) Regulation (EC) No. 1272/2008.