Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
yes
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
> 180 °C
Atm. press.:
1 013 hPa
Remarks on result:
other: Sample foamed out of apparatus when heated.
Conclusions:
Flash point is >180°C at 1013 hPa
Executive summary:

The flash point of the test substance was determined using a method based on ASTM Method D93 (Pensky-Martens Closed Cup). No flashpoint was observed when heated up to 180°C as the sample foamed out of the apparatus when heated.

Description of key information

ASTM Method D93

Key value for chemical safety assessment

Flash point at 101 325 Pa:
180 °C

Additional information

No measurable flash point when heated up to 180°C. Sample foamed out of apparatus when heated.