Registration Dossier

Physical & Chemical properties

Partition coefficient

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

Two studies on logKow are available (both reported as BMG partion coefficient, 2012-2013). The result of the slow stirring method is considered most accurate compared to a published value.

Key value for chemical safety assessment

Log Kow (Log Pow):
5.6
at the temperature of:
25 °C

Additional information

Both studies do not completely meet the validation criteria. The outcome of the slow stirring method, logKow is 5.63 (BMG 2013) is most closely to a reported value of 5.56 in the EPIWIN model (reference could not be identified based on the information provided). For risk assessment a logKow value of 5.6 is selected.