Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: non-GLP, information on study period is missing
Qualifier:
equivalent or similar to guideline
Guideline:
other: no guideline mentioned in the report
Principles of method if other than guideline:
dry sieve test (use of air stream-sieve apparatus) the weight portion of the respective sieve residues (various mesh sizes used) was determined
GLP compliance:
not specified
Type of method:
other: Not specified
Type of distribution:
other: weight distribution per size fraction
Key result
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.
No.:
#1
Size:
> 300 µm
Distribution:
0.1 %
No.:
#2
Size:
150 - 300 µm
Distribution:
1 %
No.:
#3
Size:
100 - 150 µm
Distribution:
4.7 %
No.:
#4
Size:
63 - 100 µm
Distribution:
8.4 %
No.:
#5
Size:
40 - 63 µm
Distribution:
12.3 %
No.:
#6
Size:
< 40 µm
Distribution:
73.5 %
Conclusions:
Dry sieve test was performed to determine the particle size distribution of Lowinox AH25. 94.2% of Lowinox AH25 had a particle size of < 100 um, and 73.5% had a particle size < 40 um.

Description of key information

Dry sieve test was performed to determine the particle size distribution of Lowinox AH25. 94.2% of Lowinox AH25 had a particle size of < 100 um, and 73.5% had a particle size < 40 um.

Additional information