Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

 The vapour pressure of members of this category have been measured in the range 0.0094 - 0.11 Bar at temperatures in the range 20 - 37.8°C

Key value for chemical safety assessment

Additional information

Guideline proprietary studies are available. The vapour pressure of 91052 -99 -2 at 37.8°C was measured at 0.11 bar (INEOS 2009).

The vapour pressure of 7756 -94 -7 at 37.8°C was measured at 0.02 bar (INEOS 2009). The vapour pressure of 91053 -00 -8 at 37.8°C was measured at 0.01 bar (INEOS 2009). The vapour pressure of 97280 -83 -6 at 20°C was measured at 9.4 hPa [0.0094 bar] (Evonik 2009).

These data will be read across to other members of the category.