Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report Date:
2013

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
2002
GLP compliance:
no
Type of method:
closed cup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
other: liquid
Details on test material:
Name of test material (as cited in study report): Tricyclo[3.3.1.13,7]decan-1-amine, N,N-dimethyl-
Analytical purity: >= 97%
Lot/batch No.: O 3027

Results and discussion

Flash point
Flash point:
109.5 °C
Atm. press.:
1 013.25 hPa

Any other information on results incl. tables

Results

Initial test: 110.0°C

Main test: Corrected value in °C: 109.4

The corrected flashpoint to the nearest 0.5°C is 109.5°C

Applicant's summary and conclusion