Registration Dossier

Environmental fate & pathways

Hydrolysis

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The half-life of the test material was estimated to be 206 years at pH 7.0 and 25 deg C and 20.6 years at pH 8.0 and 25 deg C.

Key value for chemical safety assessment

Half-life for hydrolysis:
20.6 yr
at the temperature of:
25 °C

Additional information

The half-life of the test material was estimated using the EPIWIN HYDROWIN Program (v2.00).