Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

No study was considered robust enough to be a key study and so a weight of evidence approach was used.
Vapour pressure.001: The vapour pressure of tributylaluminium ranged from 0.0041 mm Hg at 40 ºC to 759 mm Hg at 240 ºC.
Vapour pressure.002: The vapour pressure of tributylaluminium is < 1 hPa (< 0.75 mmHg) at 80 ºC.

Key value for chemical safety assessment

Additional information

No methodological information is available for either of the studies. As such, both were assigned a Klimisch rating of 4, and therefore neither could be considered robust enough to be a key study. A weight of evidence was adopted.

The vapour pressure at 80 ºC is 0.235 mmHg according to Vapour pressure.001 and < 0.75 mmHg according to Vapour pressure.002. This shows the two studies are approximately in agreement with each other. The low vapour pressure values indicate that exposure by inhalation would be unlikely.